package at.acdp.urweb.rtde; public class InParams { public static final String speed_slider_mask ="speed_slider_mask"; // UINT32 "0 = don't change speed slider with this input 1 = use speed_slider_fraction to set speed slider value" public static final String speed_slider_fraction ="speed_slider_fraction"; // DOUBLE new speed slider value public static final String standard_digital_output_mask ="standard_digital_output_mask"; // UINT8 Standard digital output bit mask* public static final String standard_digital_output ="standard_digital_output"; // UINT8 Standard digital outputs public static final String configurable_digital_output_mask ="configurable_digital_output_mask"; // UINT8 Configurable digital output bit mask* public static final String configurable_digital_output ="configurable_digital_output"; // UINT8 Configurable digital outputs public static final String tool_digital_output_mask ="tool_digital_output_mask"; // UINT8 "Tool digital outputs mask Bits 0-1: mask, remaining bits are reserved for future use" public static final String tool_digital_output ="tool_digital_output"; // UINT8 "Tool digital outputs Bits 0-1: output state, remaining bits are reserved for future use" public static final String standard_analog_output_mask ="standard_analog_output_mask"; // UINT8 "Standard analog output mask Bits 0-1: standard_analog_output_0 | standard_analog_output_1" public static final String standard_analog_output_type ="standard_analog_output_type"; // UINT8 "Output domain {0=current[A], 1=voltage[V]} Bits 0-1: standard_analog_output_0 | standard_analog_output_1" public static final String standard_analog_output_0 ="standard_analog_output_0"; // DOUBLE Standard analog output 0 (ratio) [0..1] public static final String standard_analog_output_1 ="standard_analog_output_1"; // DOUBLE Standard analog output 1 (ratio) [0..1] public static final String input_bit_registers0_to_31 ="input_bit_registers0_to_31"; // UINT32 "General purpose bits This range of the boolean input registers is reserved for FieldBus/PLC interface usage." public static final String input_bit_registers32_to_63 ="input_bit_registers32_to_63"; // UINT32 "General purpose bits This range of the boolean input registers is reserved for FieldBus/PLC interface usage." public static final String input_bit_register_X ="input_bit_register_X"; // BOOL "64 general purpose bits X: [64..127] - The upper range of the boolean input registers can be used by external RTDE clients (i.e URCAPS)." public static final String input_int_register_X ="input_int_register_X"; // INT32 "48 general purpose integer registers X: [0..23] - The lower range of the integer input registers is reserved for FieldBus/PLC interface usage. X: [24..47] - The upper range of the integer input registers can be used by external RTDE clients (i.e URCAPS)." public static final String input_double_register_X ="input_double_register_X"; // DOUBLE "48 general purpose double registers X: [0..23] - The lower range of the double input registers is reserved for FieldBus/PLC interface usage. X: [24..47] - The upper range of the double input registers can be used by external RTDE clients (i.e URCAPS)." }