@@ -647,11 +647,12 @@ copyCommonVariableAttributes(UA_Server *server, UA_VariableNode *node,
|
|
|
/* Use the default value from the vt if none is defined */
|
|
|
if(!value.value.type) {
|
|
|
retval = readValueAttribute(server, (const UA_VariableNode*)vt, &value);
|
|
|
- UA_LOG_INFO(server->config.logger, UA_LOGCATEGORY_SERVER,
|
|
|
- "Could not read the value of the variable type "
|
|
|
- "with error code %s", UA_StatusCode_name(retval));
|
|
|
- if(retval != UA_STATUSCODE_GOOD)
|
|
|
+ if(retval != UA_STATUSCODE_GOOD) {
|
|
|
+ UA_LOG_INFO(server->config.logger, UA_LOGCATEGORY_SERVER,
|
|
|
+ "Could not read the value of the variable type "
|
|
|
+ "with error code %s", UA_StatusCode_name(retval));
|
|
|
return retval;
|
|
|
+ }
|
|
|
}
|
|
|
|
|
|
/* Write the value to the node */
|